B. Sc. National Autonomous University of Mexico.
M. in Sc. National Institute of Astronomy, Optics and Electronics. Mexico.
M. in Ph. Imperial College of Science and Technology, England.
Ph. D., Laval University, Quebec, Canada.
Researcher at the Center for Investigations in Optics since 1986.
Research Interests:
Materials developed in the laboratory are used with visible and or infrared light (10.6 microns wavelength). These materials can be used in the fabrication of holograms, lenses, or arrays of them, and prisms with sizes from about 50 microns to several millimeters. We also fabricate pressure sensors and refractometers based on optofluidic devices.
Recent publications:
2019
- A.Arellano-Morales , J.Molina-González, H.Desirena, J.Hernandez and Sergio Calixto. FAST SINTERING METHOD OF PHOSPHOR-IN-GLASS FOR HIGH POWER LEDS. JOURNAL OF LUMINESCENCE, Volume 214, October 2019, 116546, https://doi.org/10.1016/j.jlumin.2019.116546
- Sergio Calixto, Valeria Piazza, Alan M. Gonzalez-Suarez, Jose L. Garcia-Cordero, Neil C. Bruce, Martha Rosete-Aguilar, and Guillermo Garnica LIQUID REFRACTIVE INDEX MEASURED THROUGH A REFRACTOMETER BASED ON DIFFRACTION GRATINGS. OPTICS EXPRESS, Vol. 27, Issue 24, pp. 34705-34720, (2019) , https://doi.org/10.1364/OE.27.034705
- Sergio Calixto, Valeria Piazza , Virginia Francisca Marañon-Ruiz. STIMULI-RESPONSIVE SYSTEMS IN OPTICAL HUMIDITY-DETECTION DEVICES. MATERIALS, 2019 Jan 21;12(2):327, 10.3390/ma12020327
2018
- Sergio Calixto, Nina Ganzherli,Sergey Gulyaev, and Susana Figueroa-Gerstenmaier. GELATIN AS PHOTOSENSITIVE MATERIAL. Molecules. 2018 Aug; 23(8): 2064. doi: 10.3390/molecules23082064
- Siraj Sidhik, Sandeep Surendra Panikar, Christopher Rosiles Pérez,Tzarara López Luke,Ramón Carriles,Sergio Calixto Carrera y Elder De la Rosa. INTERFACIAL ENGINEERING OF TIO2 BY GRAPHENE NANOPLATES FOR HIGH EFFICIENCY HYSTERESIS-FREE PERVSKITE SOLAR CELLS. ACS SUSTAINABLE CHEMISTRY AND ENGINEERING, https://doi.org/10.1021/acssuschemeng.8b03826
2017
- Sergio Calixto, Geminiano Martinez-Ponce, Guillermo Garnica, Susana Figueroa-Gerstenmaier. A Wavefront Division Polarimeter for the Measurements of Solute Concentrations in Solutions. Sensors 2017, 17(12), 2844; https://doi.org/10.3390/s17122844
- Sergio Calixto, Martha Rosete-Aguilar, Ismael Torres-Gomez. Liquid Temperature Measurements Using Two Different Tunable Hollow Prisms. Sensors 2017, 17(2), 266; https://doi.org/10.3390/s17020266
2016
- Calixto S, Bruce NC, Rosete-Aguilar M. Diffraction grating-based sensing optofluidic device for measuring the refractive index of liquids. OPTICS EXPRESS 24 (1), pp. 180-190. DOI: 10.1364/OE.24.000180
- Pereira MV, Minkovich VP, Espinosa-Luna R, Barmenkov YO, Calixto S. Polarimetric parameters associated to special microstructured fibers. APPLIED OPTICS, Volume: 55 No.: 18 Pags: 4865-4870, DOI: 10.1364/AO.55.004865
2015
2013
- Marcelo Vaca Pereira, Vladimir P. Minkovich, Sergio Calixto Carrera, Revista Mexicana de Fisica V. 59, p. 317 – 321(2013).
- Sergio Calixto, Martha Rosete-Aguilar, M.E. Sanchez-Morales, Margarita Calixto-Solano, “Spectrometer and Scanner with optofluidic configuration,” Applied Optics, Vol. 52 Issue 3, pp.495-504 (2013).
- Miguel Leon Rodríguez, Ramon Rodríguez Vera, Juan Rayas, Sergio Calixto, “Digital holographic microscopy through Mireau interferometric objective,” Optics and Laser Engineering, 51, 240 - 245 (2013).
2012
- Miguel Leon Rodriguez, Ramon Rodriguez Vera, Juan Rayas, Sergio Calixto, “High topographical accuracy by optical shot noise reduction in digital holograhic microscopy,” JOSA A 29, 498 – 506 (april 2012).
- Sergio Calixto, Martha Rosete Aguilar, Francisco J. Sanchez Marin, Margarita Calixto Solano, Carlos Lopez Mariscal, “Refractive index measurement through image analysis with an optofluidic device,” Optics Express 20, 2073 – 2079 (2012).
2011
- M. Leon, Ramon Rodriguez Vera, Juan Rayas, Sergio Calixto, “Amplitude and phase recovering from micro digital hologram using angular spectrum,” Revista Mexicana de Fisica 57, 31 (agosto 2011).
- Donato Luna-Moreno, David Monzon-Hernandez, Sergio Calixto, and Rafael Espinoza-Luna, “Tailored palladium/gold layer produced by conventional evaporation process for hydrogen sensing,” Optics and Laser in Engineering 49, 693 – 697 (2011).
2010
- Sergio Calixto, Martha Rosete-Aguilar, Francisco J. Sanchez-Marin,Virginia Marañon, Jose Luis Arauz Lara, Diana Mendoza Olivares, Margarita Calixto Solano, E. Militza Martinez Prado, “Optofluidic Compound microlenses made by emulsion techniques,” Optics Express 18 (18), 18703 – 18711 (2010).
2009
- Francisco Sanchez Marin, Sergio Calixto, “A novel approach to asses the emisivity of the human skin,” Journal of biomedical Optics 14, 230 – 235 (2009).
- Sergio Calixto, M.E. Sanchez, Francisco J. Sanchez – Marin, Martha – Rosete-Aguilar, Antonio Martinez richa, Karla Barrera rivera, “Optofluidic variable focus lenses,” Applied Optics 48, 2308 - 2314 (2009).
- Sergio Calixto, Francisco J. Sanchez – Marin, M.E. Sanchez-Morales, “Pressure Measurements through image analysis,” Optics Express vol 17, 17996 – 18001 (2009).
- Carmen Salazar-Hernandez, Ramon Zarraga, Sergio Alonso, Satshi sugita, Sergio Calixto, Jorge Cervantes, “Effect of solvent type on polycondensation of TEOS catalyzed by DBTL as used for stone consolidation,” Journal of Sol-Gel science and Technology 49 (3), 301 – 310 (2009).
- Carlos Villaseñor-Mora, F.J. Sanchez-Marin, and Sergio Calixto, “An indirect skin emissivity measurement in the infraed thermal range through reflection of a CO2 laser beam,” Revista Mexicana de Fisica v55, 387 – 392 (2009).